Tag: FND_NODES

  • Oracle EBS R12.2 Multi-Node Patching in Downtime Mode: Recovering a Failed Slave Node with restart=yes

    Alhamdulillah, sharing another real patching session — this one from an Oracle E-Business Suite R12.2 multi-node environment. While applying a patch in downtime mode, I encountered an interesting situation: the patch completed successfully on the master node but failed on the slave node, while the final ADOP output still showed:

    adop exiting with status = 0 (Success)

    This post walks through the complete sequence: pre-checks, the slave-node failure, investigation, recovery using restart=yes, and the SQL checks used to verify the final patch state.

    Environment

    • Oracle E-Business Suite R12.2.13
    • AD/TXK Delta 15 (ADOP C.Delta.15)
    • Two application nodes: appsnode1 (master/admin node) and webnode1 (slave/web node)
    • Oracle Database 19c on dbnode1
    • Patch mode: downtime (single file system apply; no online patching cutover involved)

    Pre-Checks Before the Apply

    Before starting the patch, I checked three things: the current ADOP session status, application processes on all application nodes, and the current file-system edition.

    From the master node:

    [applmgr@appsnode1]$ adop -status
    Node Name Node Type Phase Status
    --------------- ---------- --------------- ---------------
    appsnode1 master APPLY ACTIVE
    CLEANUP NOT STARTED
    webnode1 slave APPLY ACTIVE
    CLEANUP NOT STARTED

    I also confirmed I was operating from the run edition:

    [applmgr@appsnode1]$ echo $FILE_EDITION
    run

    Then I checked for application-tier processes:

    [applmgr@appsnode1]$ ps -ef | egrep 'FNDLIBR|FNDSM|FNDCRM|FNDOPP|oacore|forms|WebLogic|NodeManager' | grep -v grep

    There was no output, confirming the expected services were down on the master node.

    Important: In a multi-node environment, repeat these process checks on every application node. Checking only the master node is not sufficient — a condition on a slave node can otherwise go unnoticed until the apply reaches it.

    Starting the Downtime Apply

    The downtime apply was initiated from the master node:

    [applmgr@appsnode1]$ adop phase=apply apply_mode=downtime patches=<patch_number>

    ADOP manages execution across the registered application-tier nodes, so there was no need to manually start ADOP on the slave node.

    During initialization, ETCC reported missing database fixes:

    [WARNING] ETCC: The following required database fixes have not been applied to node dbnode1:
    ...
    Refer to My Oracle Support Knowledge Document 1594274.1 for instructions.

    ETCC warnings should always be reviewed before proceeding. In this case, the apply was allowed to continue based on the maintenance plan, while the outstanding database fixes were documented and tracked separately for a subsequent maintenance activity.

    Master Succeeded, Slave Failed

    The patch application succeeded on the master node but failed on the slave:

    Applying <patch> patch(es) on admin node: [appsnode1].
    txkADOPEvalSrvStatus.pl returned SUCCESS
    Applying <patch> patch(es) on node(s): [webnode1].
    Running in Serial
    [ERROR] adop phase=apply failed on Node: "webnode1"
    Summary report for current adop session:
    Node webnode1: Failed
    - Apply status: Failed
    Node appsnode1: Completed successfully
    - Apply status: Completed successfully
    adop exiting with status = 0 (Success)

    This is an important operational lesson. Despite the slave-node failure being clearly reported in the summary, the ADOP invocation ended with adop exiting with status = 0 (Success).

    Therefore, relying only on the shell return code or the final ADOP exit line is not sufficient for determining whether every application node completed successfully. The per-node summary must also be reviewed.

    I confirmed the state with:

    adop -status -detail

    which showed:

    Node Name Node Type Phase Status
    --------------- ---------- --------------- ---------------
    appsnode1 master APPLY ACTIVE
    webnode1 slave APPLY FAILED

    For automated patching this matters even more: scripts should validate the ADOP session and per-node phase status rather than treating $? = 0 alone as proof of a successful multi-node patch.

    Investigating the Slave Node

    I then logged into webnode1. Application services were expected to be completely down, so I checked for NodeManager:

    [applmgr@webnode1]$ ps -ef | grep -i nodemanager | grep -v grep
    applmgr 4148261 1 0 Jun18 ... weblogic.NodeManager -v

    A NodeManager process was still running, and had been since a previous month.

    I checked whether other WebLogic or EBS application processes were present:

    [applmgr@webnode1]$ ps -ef | grep -i weblogic | grep -v grep

    Only the NodeManager process remained. Concurrent Manager processes were also absent:

    [applmgr@webnode1]$ ps -ef | grep FNDLIBR | grep -v grep

    No output was returned.

    Since the environment was in a planned patching outage and no managed servers were running, the stale NodeManager process was stopped:

    [applmgr@webnode1]$ kill 4148261

    I then verified again:

    [applmgr@webnode1]$ ps -ef | egrep 'FNDLIBR|FNDSM|oacore|forms|WebLogic|NodeManager' | grep -v grep

    No relevant processes remained.

    A Note About Root Cause

    The presence of the stale NodeManager was an abnormal condition that needed to be corrected before retrying the patch. However, unless the ADOP logs explicitly identify that process as the reason for the failure, it is safer not to state that NodeManager was definitively the root cause.

    What can be established from this incident is:

    1. The slave-node apply failed.
    2. A stale NodeManager process was discovered on that node.
    3. The process was stopped after confirming application services were intended to be down.
    4. The failed ADOP apply subsequently completed successfully with restart=yes.

    For a formal RCA, the relevant ADOP and slave-node logs should be used to establish the exact failure mechanism.

    Also, before terminating any process, verify that:

    • It belongs to the expected EBS environment/file system.
    • No managed servers depend on it.
    • Application services are intended to be down.
    • The action complies with your production change procedure.

    Recovering the Failed Apply with restart=yes

    After cleaning up the slave node, I returned to the master node. The existing failed apply was resumed using:

    [applmgr@appsnode1]$ adop phase=apply patches=<patch_number> apply_mode=downtime restart=yes

    ADOP detected the existing session:

    Checking for existing adop sessions.
    Application tier services are down.
    Continuing with the existing session [Session ID: <n>].

    The apply was then processed successfully:

    Applying <patch> patch(es) on admin node: [appsnode1].
    txkADOPEvalSrvStatus.pl returned SUCCESS
    Applying <patch> patch(es) on node(s): [webnode1].
    Running in Serial
    txkADOPEvalSrvStatus.pl returned SUCCESS

    The final summary showed both nodes successful:

    Summary report for current adop session:
    Node webnode1: Completed successfully
    - Apply status: Completed successfully
    Node appsnode1: Completed successfully
    - Apply status: Completed successfully

    The important point here is that I resumed the existing ADOP session rather than initiating an unrelated fresh patching attempt. The recovery command was executed from the master/admin node, allowing ADOP to coordinate processing on the registered slave node.

    For the exact semantics of restart=yes in downtime mode and multi-node processing, refer to the Oracle E-Business Suite Patching Guide and the relevant My Oracle Support documentation. What I can report from this incident is the observed behaviour above: ADOP continued the existing session and both nodes subsequently reported success.

    Post-Restart Validation

    After the successful rerun, I checked the detailed ADOP status:

    [applmgr@appsnode1]$ adop -status -detail

    The nodes no longer showed a failed apply state.

    I also scanned the latest ADOP logs:

    [applmgr@appsnode1]$ adopscanlog -latest=yes
    Scanning .../log/adop/<session>/ directory ...
    No Errors.

    adopscanlog is a useful quick check after an ADOP phase because it searches the session logs for reported errors that may otherwise be easy to miss.

    SQL Verification: Confirming Patch Registration

    I don’t rely only on the ADOP console output. After patching, I also verify the database-side patch records.

    1. Check AD_BUGS

    SET LINES 200
    COL BUG_NUMBER FORMAT A15
    COL CREATION_DATE FORMAT A22
    SELECT bug_number,
    creation_date
    FROM ad_bugs
    WHERE bug_number = '<patch_number>';

    This confirms whether the specified bug/patch number is recorded in AD_BUGS. Because patch contents and registration behaviour can vary, this check should be used together with ADOP status, logs, and the relevant applied-patch records rather than as standalone proof of complete patch application. Running the same query before patching is also useful, because it establishes a clear before-and-after state.

    2. Check Applied Patch Records

    SELECT applied_patch_id,
    patch_name,
    patch_type,
    source_code,
    creation_date,
    last_update_date,
    data_model_done_flag
    FROM ad_applied_patches
    WHERE patch_name = '<patch_number>';

    Depending on the patch structure, this helps confirm the corresponding patch-driver records.

    3. Verify AD/TXK Code Levels

    COL ABBREVIATION FORMAT A15
    COL CODELEVEL FORMAT A25
    SELECT abbreviation,
    codelevel
    FROM ad_trackable_entities
    WHERE abbreviation IN ('ad','txk')
    ORDER BY abbreviation;

    For this environment the query returned:

    ABBREVIATION CODELEVEL
    --------------- -------------------------
    ad C.15
    txk C.15

    This check is especially important when applying AD/TXK-related patches or preparing for an EBS Release Update Pack.

    4. Verify the EBS Release

    SELECT release_name
    FROM fnd_product_groups;

    Expected for this environment: 12.2.13.

    5. Verify Node Registration

    COL NODE_NAME FORMAT A25
    SELECT node_name,
    support_cp,
    support_forms,
    support_web,
    support_admin
    FROM fnd_nodes
    ORDER BY node_name;

    This provides a quick sanity check of application-tier node registration and responsibilities.

    6. Verify ADOP Valid Nodes

    SELECT *
    FROM adop_valid_nodes
    ORDER BY node_name;

    Both application nodes should appear as expected.

    In this case, the final checks confirmed:

    • The bug/patch number was recorded in AD_BUGS.
    • The corresponding applied-patch records were present.
    • AD and TXK were at the expected C.15 level.
    • EBS remained at Release 12.2.13.
    • Both application nodes were properly registered in FND_NODES.
    • Both nodes appeared correctly in ADOP_VALID_NODES.
    • adopscanlog reported no errors after the successful rerun.

    Together, these checks provide much stronger verification than relying on the final ADOP console message alone.

    Complete the Session with Cleanup

    After confirming the apply completed successfully, the session still showed:

    CLEANUP NOT STARTED

    The cleanup phase was then run:

    adop phase=cleanup

    After cleanup, perform another status and log review to make sure the session is in the expected final state.

    Key Takeaways

    Don’t rely only on ADOP’s exit status in a multi-node environment. In this incident, ADOP printed status = 0 (Success) even though the per-node summary clearly showed the slave node had failed.

    Check every application node before a downtime apply. A clean process list on the master does not guarantee the slave nodes are equally clean.

    Use the per-node ADOP status as part of your success criteriaadop -status -detail.

    Investigate the failed node before retrying. In this case a stale NodeManager process was discovered and removed before the successful retry. Unless supported by the logs, however, avoid treating correlation as a confirmed root cause.

    Resume the existing failed apply appropriately — after correcting the condition on the slave node, the existing apply was resumed from the master node with restart=yes.

    Use adopscanlog -latest=yes after the rerun.

    Verify patch registration in the databaseAD_BUGS, AD_APPLIED_PATCHES, AD_TRACKABLE_ENTITIES, FND_NODES, ADOP_VALID_NODES, FND_PRODUCT_GROUPS.

    Run ETCC and review its findings. If required database fixes are deferred, document and track them for the appropriate maintenance window rather than allowing them to become forgotten technical debt.

    Complete the ADOP cleanup phaseadop phase=cleanup.

    Final Thought

    Multi-node EBS patching adds a layer of validation that is easy to overlook: success on the master node does not automatically mean success across the application tier.

    The most useful lesson from this incident was not the retry command itself, but the validation process around it:

    Check every node → read the ADOP per-node summary → investigate the failed node → resume the existing session → scan the logs → verify the database records → complete cleanup.

    That sequence gives you a far more defensible and auditable patching result than relying on a single Success message at the end of the command.

    I hope this helps anyone troubleshooting a failed application-tier node during Oracle E-Business Suite R12.2 downtime patching. Feel free to leave a comment if you have questions.


    Disclaimer: The views expressed on this blog are my own and do not reflect the views of my employer or any client. All environment names, hostnames, and identifiers used in this post are anonymized. Always test in a non-production environment before applying any change to production.

  • Oracle EBS R12.2 Clone Redirects to PROD After Login: Diagnosing Stale Configuration References

    When you finish cloning an Oracle E-Business Suite R12.2 environment, the moment of truth is the login page. You hit the clone’s web entry URL, the page loads, you type your credentials… and the browser quietly throws you onto the production URL. On a multi-node app tier this is more than an annoyance — it means your freshly cloned, supposedly isolated environment is reaching back into PROD, and a careless tester could authenticate against the wrong system entirely.

    I ran into exactly this on a recent R12.2.11 clone built on Oracle Cloud Infrastructure: a three-node application tier sharing a single run/patch file system over an FSS (File Storage Service) NFS mount. The clone came up, services started, but every login attempt redirected to the PROD web entry host. The initial investigation uncovered two primary issues — phantom WebLogic managed servers carried over from the source domain, and a missing DNS A-record for the clone’s web entry hostname. Along the way I also identified several other clone-related configuration areas that can produce the same symptom, including stale profile options, OHS configuration remnants, load balancer redirects, and custom code references.

    This post walks through how the symptom presents, how to diagnose it cleanly, and the supported way to fix each cause.

    Throughout, I use placeholder names — clone-apps.example.com for the clone web entry host, prod-apps.example.com for production, and appnode1/2/3 for the three app-tier nodes. Substitute your own values.


    The architecture (why a shared file system matters here)

    The clone app tier looked like this:

    • Three application-tier nodes (appnode1, appnode2, appnode3).
    • A shared dual file system (fs1 run / fs2 patch) hosted on an OCI FSS NFS export, mounted identically on all three nodes.
    • A single WebLogic domain (EBS_domain_<SID>) living on that shared file system.

    The shared file system is the detail that makes the “phantom managed server” problem sticky. Because config.xml and the managed-server definitions physically live on the shared FSS mount, any leftover managed-server entries from the source domain are visible to every node at once. AutoConfig regenerates context-driven artifacts, but it does not, on its own, delete managed servers that no longer belong to the topology.


    The symptom

    After adcfgclone completed and the application services started:

    • The clone login page (https://clone-apps.example.com:<port>/OA_HTML/AppsLogin) rendered correctly.
    • On submitting credentials — or sometimes immediately on the redirect to the home page — the browser landed on https://prod-apps.example.com/....
    • The WebLogic Admin Console showed more managed servers than the three-node clone should have, several of them in an unreachable / shutdown state.

    Two independent problems reinforced each other: stale host references remained inside the cloned WebLogic topology, while the clone web entry hostname could not be resolved correctly. Either issue can cause redirect anomalies, but together they consistently redirected users back to PROD.


    First, rule out the context file

    Before investigating WebLogic, verify the clone context file itself doesn’t still contain production hostnames. AutoConfig can only generate correct configuration if the context values are correct, so everything downstream is built from here:

    grep -i "prod-apps.example.com" $CONTEXT_FILE
    grep -i "prod" $CONTEXT_FILE

    If PROD survives in the context, fix it there and re-run AutoConfig before chasing anything downstream — otherwise you’ll be debugging generated artifacts while the source of the bad values sits upstream.


    Root cause 1 — Phantom WebLogic managed servers

    A correctly provisioned three-node oacore service should have oacore_server1, oacore_server2, oacore_server3 (and the matching oafm, forms, forms-c4ws servers per node). The cloned domain carried extra managed servers that mapped to the source environment’s nodes — servers that pointed at listen addresses and host references belonging to PROD.

    These phantom servers do three harmful things:

    1. They keep PROD host references alive inside config.xml.
    2. They confuse the EBS service control and the Admin Server’s view of the cluster.
    3. They can answer (or fail to answer) requests in ways that surface PROD URLs.

    Diagnosing it

    Inventory what the domain actually contains versus what the topology should be:

    # What managed servers does the domain config believe in?
    grep -E "<name>|<listen-address>" \
    $EBS_DOMAIN_HOME/config/config.xml | grep -iE "oacore|oafm|forms|server"
    # What does EBS think the nodes are?
    sqlplus apps/<pwd> <<'EOF'
    COL node_name FORMAT a20
    COL server_address FORMAT a18
    COL support_cp FORMAT a10
    COL support_web FORMAT a10
    COL support_admin FORMAT a13
    SELECT node_name,
    NVL(server_address,'-') AS server_address,
    NVL(support_cp,'-') AS support_cp,
    NVL(support_web,'-') AS support_web,
    NVL(support_admin,'-') AS support_admin
    FROM fnd_nodes
    ORDER BY node_name;
    EOF

    Any managed server or fnd_nodes row that references a host which is not one of appnode1/2/3 is a phantom artifact from the source.

    It’s also worth checking the role assignments — sometimes the hostname is correct but node registrations are duplicated or carry the wrong roles:

    COL node_name FORMAT a30
    COL support_db FORMAT a10
    SELECT node_name,
    support_db,
    support_cp,
    support_web,
    support_admin
    FROM fnd_nodes
    ORDER BY node_name;

    Fixing it (the supported way)

    Do not hand-edit config.xml. EBS R12.2 ships a provisioning utility to add and delete managed servers cleanly, keeping the domain, AutoConfig, and the database registration in sync. Stop the affected services first, then delete each phantom server:

    # Stop the managed servers / services before topology changes
    $ADMIN_SCRIPTS_HOME/adstpall.sh apps/<apps_pwd>
    # Delete a phantom managed server (repeat per orphaned server / service type)
    perl $AD_TOP/patch/115/bin/adProvisionEBS.pl \
    ebs-delete-managedserver \
    -contextfile=$CONTEXT_FILE \
    -managedsrvname=oacore_server4 \
    -servicetype=oacore \
    -promptmsg=hide

    After removing every phantom server, run AutoConfig on each app node so the context, the domain, and fnd_nodes agree:

    $ADMIN_SCRIPTS_HOME/adautocfg.sh

    Then confirm fnd_nodes only lists the three real clone nodes, and the Admin Console only shows the expected per-node managed servers. If you find stale node rows after the clean-up, the standard FND_CONC_CLONE.SETUP_CLEAN → AutoConfig sequence on each tier is the canonical way to rebuild the node registration. Run it as APPS, then re-run AutoConfig on every tier:

    EXEC FND_CONC_CLONE.SETUP_CLEAN;
    COMMIT;

    (Always take that step with the DBA team’s sign-off on a shared environment.)


    Root cause 2 — The missing DNS A-record

    With the phantom servers gone, the redirect still misbehaved intermittently. The reason was simpler and entirely outside EBS: the clone’s web entry hostname had no DNS A-record.

    The login flow builds its target URL from the AutoConfig web entry variables. Check them:

    grep -E "s_webentryhost|s_webentrydomain|s_webentryurlprotocol|s_active_webport|s_url_protocol|s_login_page" \
    $CONTEXT_FILE

    It’s worth proving the generated login URL, not just the host variable — if AutoConfig hasn’t fully taken, these still show a PROD host and you’ll be chasing DNS for a problem that lives in the context:

    grep -i "webentry" $CONTEXT_FILE
    grep -i "login_page" $CONTEXT_FILE

    The context correctly named clone-apps.example.com as s_webentryhost. But on the app nodes — and for clients — that name did not resolve:

    nslookup clone-apps.example.com
    # ** server can't find clone-apps.example.com: NXDOMAIN
    dig +short clone-apps.example.com
    # (empty)

    Because the clone web entry host was not resolvable, requests that relied on generated URLs could not consistently resolve back to the clone environment. At the same time, stale PROD references still lived inside the cloned WebLogic topology. Together these two conditions caused redirects to be generated using PROD host information, sending users away from the clone — which is why fixing the phantom servers alone wasn’t enough. To be clear, EBS does not contain any built-in mechanism that redirects a clone to production. Such redirects are almost always caused by stale configuration, profile options, WebLogic topology artifacts, load balancer settings, or DNS resolution — not by EBS doing anything magical. The browser is simply following a redirect built from stale host values. Name resolution has to work and the topology has to be clean.

    Fixing it

    Add an A-record for the clone web entry host in the appropriate DNS zone, pointing at the clone’s web-tier listen address (or its load balancer / OCI public-or-private IP, depending on your access path):

    clone-apps.example.com. IN A 10.x.x.x

    If a DNS change isn’t immediately possible and you only need the app nodes to resolve it for validation, a temporary /etc/hosts entry on each of appnode1/2/3 will confirm the theory — but a proper A-record is the real fix, because clients need to resolve it too:

    10.x.x.x clone-apps.example.com clone-apps

    Verify resolution from each node and re-test:

    for n in appnode1 appnode2 appnode3; do
    echo "== $n =="; ssh $n "nslookup clone-apps.example.com | tail -3"
    done

    Before concluding the issue persists, test using an incognito/private browser session or clear the browser cache. Browsers frequently cache redirects, cookies, and DNS information that can make a corrected environment appear unchanged.


    Root cause 3 — Stale profile option URLs (the other usual suspect)

    Even when DNS resolves and the WebLogic topology is clean, a clone can still throw users at PROD because profile option values were copied straight from the source. These are among the most common causes of a redirect-to-PROD, and they deserve a deliberate check rather than a passing glance. The usual culprits are APPS_WEB_AGENT, APPS_FRAMEWORK_AGENT, APPS_SERVLET_AGENT, and ICX_FORMS_LAUNCHER.

    Target them directly:

    COL profile_option_name FORMAT a30
    COL profile_option_value FORMAT a80
    SELECT fpo.profile_option_name,
    fpov.profile_option_value
    FROM fnd_profile_option_values fpov,
    fnd_profile_options_vl fpo
    WHERE fpov.profile_option_id = fpo.profile_option_id
    AND fpo.profile_option_name IN
    ('APPS_WEB_AGENT',
    'APPS_FRAMEWORK_AGENT',
    'APPS_SERVLET_AGENT',
    'ICX_FORMS_LAUNCHER');

    Or sweep more broadly for any value still carrying a PROD host:

    COL profile_option_name FORMAT a30
    COL profile_option_value FORMAT a80
    SELECT fpo.profile_option_name,
    fpov.profile_option_value
    FROM fnd_profile_option_values fpov,
    fnd_profile_options_vl fpo
    WHERE fpov.profile_option_id = fpo.profile_option_id
    AND UPPER(fpov.profile_option_value) LIKE '%PROD%';

    Most of these are AutoConfig-managed, so the right fix is almost always to correct the context and re-run AutoConfig rather than to update the profile value by hand. Hand-updating a profile that AutoConfig owns just means it reverts on the next run. If AutoConfig keeps recreating the wrong value, fix the context file or web entry settings first; otherwise the next AutoConfig run simply reintroduces the problem.


    Other places a PROD reference hides: OHS and the OCI load balancer

    A surprising share of clone redirects originate outside the database and the WebLogic domain entirely — in the web tier configuration that AutoConfig generates, or in the load balancer sitting in front of it. Worth checking these early rather than last.

    Oracle HTTP Server (OHS). Generated OHS config — mod_wl_ohs.conf chief among them — can carry PROD host references. Rather than hard-coding version-specific paths, grep the web-tier and FMW homes broadly:

    grep -R "prod-apps.example.com" \
    $INST_TOP \
    $EBS_DOMAIN_HOME/config \
    $FMW_HOME \
    $ORACLE_HOME 2>/dev/null

    OCI load balancer / reverse proxy. If an OCI Load Balancer (or any reverse proxy) fronts the environment, the redirect can be introduced at that layer even after EBS is fully corrected. Verify:

    • Host header preservation — the backend should receive the clone host, not a rewritten PROD one.
    • Backend set configuration — backends point at the clone app nodes, not PROD.
    • SSL/TLS termination — the protocol and host the LB forwards match what AutoConfig expects (s_webentryurlprotocol, s_active_webport).
    • Redirect rules / rule sets — no listener rule is rewriting the host to PROD.

    I’ve seen an OCI LB listener keep sending users to PROD long after the EBS tier itself was spotless, purely because of a stale redirect rule on the listener.

    Custom code and JARs. Customizations are a notorious hiding place — hardcoded URLs in custom packages, JSPs, or Java survive every clone untouched by AutoConfig. Grep the custom homes too:

    grep -R "prod-apps.example.com" \
    $XX_TOP \
    $JAVA_TOP \
    $CUSTOM_TOP 2>/dev/null

    Validation checklist after remediation

    1. nslookup / dig resolves clone-apps.example.com from all three app nodes and from a client workstation.

    2. WebLogic Admin Console lists only the expected per-node managed servers, all in RUNNING state.

    3. fnd_nodes contains only appnode1/2/3 (check support_cp, support_web, support_admin); no PROD host references remain.

    4. No stale source context files are still registered. Old registrations sometimes survive a clone and cause confusion later during AutoConfig or service management:

    COL node_name FORMAT a20
    COL ctx_file FORMAT a60
    SELECT node_name,
    ctx_type,
    NVL(path,'-') AS ctx_file,
    status
    FROM fnd_oam_context_files
    WHERE status = 'S'
    ORDER BY node_name;

    In a clean clone, every active context file should belong to the clone environment. Any remaining source-environment context registration should be reviewed and removed before further AutoConfig runs.

    5. The profile options from Root cause 3 (APPS_WEB_AGENT, APPS_FRAMEWORK_AGENT, APPS_SERVLET_AGENT, ICX_FORMS_LAUNCHER) all carry clone values, not PROD — re-run the targeted query from that section to confirm.

    6. The login page loads from the clone URL and — critically — the post-login redirect stays on clone-apps.example.com, never bouncing to prod-apps.example.com.

    7. Sweep the entire configuration for the PROD hostname, not just the context file. PROD remnants love to hide in OHS configs, mod_wl_ohs.conf, generated XML, and custom integrations:

    grep -R "prod-apps.example.com" \
    $INST_TOP \
    $EBS_DOMAIN_HOME/config \
    $FMW_HOME 2>/dev/null

    Anything this turns up needs to be corrected (and usually re-generated via AutoConfig) before users find it for you.

    8. No context file registered in the database still points at a PROD path. Stale PROD context registrations can cause odd behaviour long after the clone:

    COL node_name FORMAT a20
    COL path FORMAT a70
    SELECT node_name,
    path
    FROM fnd_oam_context_files
    WHERE UPPER(path) LIKE '%PROD%';

    9. If an OCI Load Balancer or reverse proxy fronts the environment, verify its listener rules, backend sets, host-header forwarding, and SSL termination settings contain no PROD references.


    Lessons learned / a small post-clone checklist

    Cloning R12.2 onto a shared file system multi-node tier adds two checks that single-node clones let you skip:

    • Audit the managed-server topology immediately after adcfgclone. On a shared file system the source’s managed servers ride along inside config.xml. Delete phantoms with adProvisionEBS.pl ebs-delete-managedserver, never by editing XML, and re-run AutoConfig.
    • Resolve the web entry hostname before you trust the login page. A clone that “logs you into PROD” is very often a DNS problem wearing an EBS costume. Create the A-record as part of the clone runbook, not as a reaction to the redirect.
    • Treat a redirect-to-PROD as a stop-the-line event. Until both topology and name resolution are clean, assume the clone can still touch production and keep testers out.
    • Run FND_CONC_CLONE.SETUP_CLEAN before AutoConfig in cloned environments. This rebuilds node registrations and context metadata cleanly and helps prevent stale topology information from the source environment persisting in the clone. (On a shared environment, run it with the DBA team’s sign-off.)

    In this case, three unglamorous root causes — leftover managed servers, a missing DNS record, and stale profile option URLs — combined to produce the redirect. In practice, however, most redirect-to-PROD incidents come down to one broader problem: stale production references surviving the clone process. The fastest path to resolution is a systematic sweep of WebLogic, DNS, profile options, context files, OHS configuration, load balancers, and custom code until every production reference is gone.


    Have you hit a different flavour of the clone redirect? The web entry variables, SSL/load-balancer termination, and s_login_page overrides each have their own way of sending you to the wrong host — happy to compare notes in the comments.